Non-intercepting DC current measurement
100 times more precise than Hall effect devices
High resolution, high robustness to discharges
Damage level: 100kA, 4/10µs discharges – DC, unlimited
Bandwidth DC to 4 kHz | Range ± 1mA to ± 20A | Resolution < 10µA |
A useful property of Magnetic Current Sensors is that the vector sum of all currents passing through the aperture is measured. Any source-to-load leakage or breakdown current within the sensor bandwidth can be measured in amplitude and phase if all cables to the load are passed through the sensor. The source may be a battery, an ac single- or multi-phase line, or a multi-phase ac line from a motor drive. The load may be a complete system like an automobile, an ac to dc inverter, or a variable speed motor. This measurement of unbalanced, leakage, or breakdown current may be useful for production test or alternatively for long-term system condition monitoring.
Return ground currents, DC and AC
Leakage current, DC and AC
Sum of low currents
Small difference of high currents
Low current at high voltage
Power tube electrode current
Electrostatic corona discharge
Electrochemically induced currents
Standby systems charging currents
Full scale range | Any value from ±1mA to ±20A, |
Bandwidth | DC up to 4kHz, depending on range |
Output | ±10V bipolar, buffered, 20 mA max |
Resolution | <10μA (1s integration) |
Linearity error | <0.1% FS |
Absolute accuracy | ± 0.5% FS |
Large aperture 82mm
Accuracy independent of
conductor position